Our multi-channel signal conditioning modules provide separate A/D conversion on each channel and up to 24-bit resolution with anti-aliasing filters. Perfect simultaneous sampling for all analog input modules. You are absolutely flexible with the user-exchangeable TRION3 & TRION modules – just insert them in your suitable DEWETRON DAQ system.

There are two module series: The highspeed TRION3  modules are only compatible with the DEWE3 chassis. But TRION modules can be used in both, DEWE3 and DEWE2 chassis.

Choose between a wide range of modules:

ANALOG MODULES
POWER MODULES
SUB-MODULES
DIGITAL MODULES
ANALOG OUTPUT MODULES

ANALOG MODULES

ANALOG MODULES PDF
CHANNELS SAMPLE RATE/CH.
RESOLUTION ISOLATION CONNECTOR
TYPES
 TRION3 -1850-MULTI


Bridge IconVibration Icon100 Volt IconRTD IconPotentiometer IconModular Smart Interfaces IconCAN IconCounter Inputs Icon PDF Download 4 or 8 5 MS/s 24-bit
>2 MS/s: 18-bit
ISO 4 D-SUB or
8 LEMO 0B
 TRION3 -1820-MULTI


Bridge IconVibration Icon100 Volt IconRTD IconPotentiometer IconModular Smart Interfaces IconCAN IconCounter Inputs Icon PDF Download 4 or 8 2 MS/s 24-bit
>2 MS/s: 18-bit
ISO 4 D-SUB or
8 LEMO 0B
TRION-1820-MULTI

Bridge IconVibration Icon100 Volt IconRTD IconPotentiometer IconModular Smart Interfaces IconCAN IconCounter Inputs Icon PDF Download 4 2 MS/s 24-bit
>2 MS/s: 18-bit
ISO 4 D-SUB
TRION-2402-MULTI


Bridge IconVibration Icon100 Volt IconCurrent IconRTD IconPotentiometer IconModular Smart Interfaces IconCAN Icon PDF Download 4 or 8 200 kS/s 24-bit ISO 4 D-SUB or
8 LEMO 0B
TRION-1620-ACC

100 Volt IconCurrent IconVibration IconCounter Inputs Icon Download the Datasheet here 6 2 MS/s 24-bit
>1 MS/s: 16-bit
ISO 6 BNC or LEMO 1B
TRION-1620-LV

100 Volt IconCurrent Icon Download the Datasheet here 6 2 MS/s 24-bit
>1 MS/s: 16-bit
ISO 6 BNC or LEMO 1B
TRION-1810-HV

1000 Volt Download the Datasheet here 4 to 8 1 MS/s 24-bit ISO Safety banana,
CAT III 1000 V
 TRION3 -1810-SUB-8

600 Volt IconCurrent Icon Download the Datasheet here 8 1 MS/s 20-bit ISO Safety banana
TRION-1603-LV

100 Volt Icon Download the Datasheet here 6 250 kS/s 16-bit ISO 6 BNC or LEMO 1B
TRION-2402-dSTG


Bridge IconVibration Icon10 Volt IconCurrent IconRTD IconPotentiometer Icon Download the Datasheet here 6 or 8 200 kS/s 24-bit 8 LEMO 0B or
8 RJ45
TRION-2402-dACC


Vibration Icon100 Volt IconCurrent IconCounter Inputs IconRTD IconPotentiometer Icon Download the Datasheet here 6 or 8 200 kS/s 24-bit 6 BNC or
8 SMB
 TRION3 -1802-dLV

10 Volt IconCounter Inputs IconDigital Input/OutputCAN IconModular Smart Interfaces (CB16) Download the Datasheet here 16 or 32 200 kS/s
100 kS/s
18-bit
24-bit
D-SUB
 TRION3 -1600-dLV

10 Volt IconCounter Inputs IconDigital Input/OutputCAN IconModular Smart Interfaces (CB16) Download the Datasheet here 16 or 32 20 kS/s 16-bit D-SUB
Compatibility: The highspeed DEWE3 systems support both, TRION3 and TRION modules. The DEWE2 systems only support TRION modules.
Here you find the overview of our DAQ systems

DIGITAL MODULES

DIGITAL MODULES PDF CHANNELS SAMPLE RATE/CH.
RESOLUTION ISOLATION FEATURES
TRION-CNT

Counter Inputs IconDigital Input/Output Download the Datasheet here 6 2 MS/s 80 MHz ISO 6 channel advanced counter
TRION-DI-48

Digital Input/Output Download the Datasheet here 48 2 MS/s 500 nsec ISO 48 highspeed digital IN
TRION-BASE

Counter Inputs IconDigital Input/OutputAbsolute IRIG Time Icon Download the Datasheet here 2 MS/s 80 MHz Basic IO card with simple IRIG sync and 2 counter
TRION-VGPS-V3

Counter Inputs IconDigital Input/OutputAbsolute IRIG Time IconGPS IconAbsolute PTP Time Icon Download the Datasheet here 2 MS/s 0.01 km/h
<10 cm
100 Hz GNSS receiver for automotive applications
TRION-TIMING-V3

Counter Inputs IconDigital Input/OutputAbsolute IRIG Time IconGPS IconAbsolute PTP Time Icon Download the Datasheet here 2 MS/s 12.5 nsec Applies precision absolute time to measured data
TRION-CAN

CAN Icon Download the Datasheet here 4 1 MBit ISO D-SUB
TRION-ARINC

Download the Datasheet here 4 or 16 Decoding of ARINC429 signals, export of decoded signals
TRION-MIL1553

Download the Datasheet here 1 or 4 Decoding of MIL-STD-1553 signals, export of decoded signals
TRION-EtherCAT-1-SLAVE

Digital Input/Output Download the Datasheet here 100 500 S/s Measurement data output
Compatibility: The highspeed DEWE3 systems support both, TRION3 and TRION modules. The DEWE2 systems only support TRION modules.
Here you find the overview of our DAQ systems

POWER MODULES

POWER MODULES PDF CHANNELS SAMPLE RATE/CH. RESOLUTION ISOLATION CONNECTOR
TYPES
TRION3 -1810M-POWER

1000 Volt Download the Datasheet here 8 (4 U / 4 I) 10 MS/s 18-bit ISO Fixed: 4 x Safety banana,
CAT III 1000 V

Exchangeable:
4 x Sub-Modules
TRION3 -1820-POWER

1000 Volt Download the Datasheet here 8 (4 U / 4 I) 2 MS/s 18-bit ISO Fixed: 4 x Safety banana,
CAT III 1000 V

Exchangeable:
4 x Sub-Modules
TRION-1820-POWER

1000 Volt Download the Datasheet here 8 (4 U / 4 I) 2 MS/s 24-bit ISO Fixed: 4 x Safety banana,
CAT III 1000 V

Exchangeable:
4 x Sub-Modules
TRION-1810-HV

1000 Volt Download the Datasheet here 8 (4 U / 4 I) 1 MS/s 24-bit ISO Fixed: 4 x Safety banana,
CAT III 1000 V

Exchangeable:
4 x Sub-Modules
TRION3 -1810-SUB-8

600 Volt IconCurrent Icon Download the Datasheet here 8 1 MS/s 18-bit ISO Fixed: 0

Exchangeable:
8 x Sub-Modules
Compatibility: The highspeed DEWE3 systems support both, TRION3 and TRION modules. The DEWE2 systems only support TRION modules.
Here you find the overview of our DAQ systems

ANALOG OUTPUT MODULES

ANALOG OUTPUT MODULES PDF CHANNELS SAMPLE RATE/CH.
RESOLUTION ISOLATION CONNECTOR
TYPES
 TRION3 -1850-MULTI-AOUT-8

Icon AOUTBridge IconVibration Icon100 Volt IconRTD IconPotentiometer IconModular Smart Interfaces IconCAN IconCounter Inputs Icon Download the Datasheet here IN: 8
OUT: 8
IN: 5 MS/s
OUT: 2.5 MS/s
IN: 24-bit
OUT: 32-bit
IN: ISO
OUT: ISO
IN: LEMO 0B
OUT: D-SUB, BNC
TRION3 -1820-MULTI-AOUT-8

Icon AOUTBridge IconVibration Icon100 Volt IconRTD IconPotentiometer IconModular Smart Interfaces IconCAN IconCounter Inputs Icon Download the Datasheet here IN: 8
OUT: 8
IN: 2 MS/s
OUT: 2.5 MS/s
IN: 24-bit
OUT: 32-bit
IN: ISO
OUT: ISO
IN: LEMO 0B
OUT: D-SUB, BNC
  TRION3 -AOUT-8

Icon AOUT Download the Datasheet here OUT: 8 2.5 MS/s Up to 32-bit ISO OUT:
D-SUB, BNC
Compatibility: The highspeed DEWE3 systems support both, TRION3 and TRION modules. The DEWE2 systems only support TRION modules.
Here you find the overview of our DAQ systems

SUB-MODULES

SUB-MODULES PDF RANGE SAFETY BANDWIDTH CONNECTOR EXCHANGE
BY USER
SUB-MODULES FOR CURRENT INPUT (directly & sensors)
Current transducer module
TRION-SUB-CT
Current transducer Module for direct input Download the PDF here 1 ARMS
(±2 AP2P)
0.5 ARMS
(±1 AP2P)
0.25 ARMS
(±0.5 AP2P)
0.1 ARMS
(±0.2 AP2P)
Not isolated.
Depending on connected current clamp
5 MHz D-SUB-9 socket Yes
20 A module
TRION-POWER-SUB-CUR-20A
Download the PDF here 20 ARMS
(±40 APEAK)
CAT II 600 V, unfused 300 kHz Safety banana (male) Yes

2 A module
TRION-POWER-SUB-CUR-2A
Download the PDF here 2 ARMS
(±4 APEAK)
CAT II 600 V, unfused 300 kHz Safety banana (male) Yes

1 A module
TRION-POWER-SUB-CUR-1A
Download the PDF here 1 ARMS
(±2 APEAK)
CAT II 600 V, unfused 300 kHz Safety banana (male) Yes

0.2 A module
TRION-POWER-SUB-CUR-02A
Download the PDF here 0.2 ARMS
(±0.4 APEAK)
CAT II 600 V, unfused 300 kHz Safety banana (male) Yes
SUB-MODULES FOR VOLTAGE INPUT
Voltage Icon 1 V module
TRION-POWER-SUB-dLV-1V
Download the PDF here 1 VRMS
(±2 VPEAK)
Not isolated.
Depending on connected current clamp
5 MHz D-SUB-9 socket Yes
Voltage Icon 5 V module
TRION-POWER-SUB-dLV-5V
Download the PDF here 5 VRMS
(±10 VPEAK)
5 MHz D-SUB-9 socket Yes
Voltage Icon Clamp input module
TRION-POWER-SUB-dLV-1
Download the PDF here 5 VRMS
(±10 VPEAK)
150 kHz D-SUB-9 socket Yes
Voltage Icon 600 V module
TRION-SUB-600V
Download the PDF here 600 VRMS
(±1500 VPEAK)
CAT II 600 V, isolated 300 kHz Safety banana Yes
Voltage Icon 5 V module
TRION-SUB-5V
Download the PDF here 5 VRMS
(±10 VPEAK)
CAT II 600 V, isolated 300 kHz Safety banana Yes
Voltage Icon Seamless auto-range module
TRION-SUB-XV
Download the PDF here 600 VRMS
(±850 VPEAK)60 VRMS
(±100 VPEAK)
6 VRMS
(±10 VPEAK)
0.6 VRMS
(±1 VPEAK)
CAT II 600 V, isolated 300 kHz Safety banana Yes

Compatibility &
Sampling rates

There are two module series:
The highspeed  TRION3  modules provide sampling rates up to 10 MS/s and are only compatible with the DEWE3 chassis.
But TRION modules can be used in both, DEWE3 and DEWE2 chassis with sampling rates up to 2 MS/s.

TRION3 & TRION modules record many disparate data sources in perfect synchronization: analog, digital, counter/encoders, GPS, CAN, timing, etc.

Signal conditioning with simultaneous sampling

Simultaneous sampling TRION3 & TRION signal conditioning modules are the heart and soul of the DEWETRON data acquisition systems.

TRION3 & TRION modules combine the power of simultaneous sampling and 24-bit ADC technology with advanced DEWETRON signal conditioning – plug one convenient module right into your DEWETRON system.

Plug’n’play TRION3 & TRION modules

Choose your TRION3 & TRION modules, plug them into your DEWE3 or DEWE2 instrument, turn the system on and get to work!

The module is automatically identified and configured within the software as soon as it is launched.

Choose between a wide range of  TRION3  and TRION modules in the tables above:

ANALOG MODULES DIGITAL MODULES POWER MODULES ANALOG OUTPUT MODULES
Back to top
Contact us Contact us

Do you have a question?

Kontakt-Formular