The Measurable difference.

Multifunctional TRION(3) Modules

Isolated TRION3 & TRION MULTI Modules

Looking for a future-proof DAQ solution that offers the flexibility for tomorrow with no drawbacks? Then choose the multifunctional TRION(3)-MULTI signal conditioning modules that are perfect for your isolated multi-purpose DAQ applications.

There are two module series: The highspeed  TRION3  modules are only compatible with the DEWE3 chassis. But TRION modules can be used in both, DEWE3 and DEWE2 chassis.

 

TRION(3)-MULTI MODULES OVERVIEW

MULTI MODULES PDF
CHANNELS SAMPLE RATE/CH.
RESOLUTION ISOLATION CONNECTOR
TYPES
  TRION3 -1850-MULTI


Bridge IconVibration Icon100 Volt IconRTD IconPotentiometer IconModular Smart Interfaces IconCAN IconCounter Inputs Icon PDF Download 4 or 8 5 MS/s 24-bit
>2 MS/s: 18-bit
ISO 4 D-SUB or
8 LEMO 0B
  TRION3 -1820-MULTI


Bridge IconVibration Icon100 Volt IconRTD IconPotentiometer IconModular Smart Interfaces IconCAN IconCounter Inputs Icon PDF Download 4 or 8 2 MS/s 24-bit
>2 MS/s: 18-bit
ISO 4 D-SUB or
8 LEMO 0B
TRION-1820-MULTI

Bridge IconVibration Icon100 Volt IconRTD IconPotentiometer IconModular Smart Interfaces IconCAN IconCounter Inputs Icon PDF Download 4 2 MS/s 24-bit
>2 MS/s: 18-bit
ISO 4 D-SUB
TRION-2402-MULTI


Bridge IconVibration Icon100 Volt IconCurrent IconRTD IconPotentiometer IconModular Smart Interfaces IconCAN Icon PDF Download 4 or 8 200 kS/s 24-bit ISO 4 D-SUB or
8 LEMO 0B
  TRION3 -1850-MULTI-AOUT-8

Icon AOUTBridge IconVibration Icon100 Volt IconRTD IconPotentiometer IconModular Smart Interfaces IconCAN IconCounter Inputs Icon Download the Datasheet here IN: 8
OUT: 8
IN: 5 MS/s
OUT:
2.5 MS/s
IN: 24-bit
OUT: 32-bit
ISO IN: LEMO 0B
OUT: D-SUB, BNC
  TRION3 -1820-MULTI-AOUT-8

Icon AOUTBridge IconVibration Icon100 Volt IconRTD IconPotentiometer IconModular Smart Interfaces IconCAN IconCounter Inputs Icon Download the Datasheet here IN: 8
OUT: 8
IN: 2 MS/s
OUT:
2.5 MS/s
IN: 24-bit
OUT: 32-bit
ISO IN: LEMO 0B
OUT: D-SUB, BNC
  TRION3 -AOUT-8

Icon AOUT Download the Datasheet here OUT: 8 2.5 MS/s Up to 32-bit ISO OUT:
D-SUB, BNC
Compatibility: The highspeed DEWE3 systems support both, TRION3 and TRION modules. The DEWE2 systems only support TRION modules.
Here you find the overview of our DAQ systems

10+ measurement modes for almost every sensor and application:

  • 9 native modes: bridge, voltage, current, IEPE, resistance, potentiometer, temperature (RTD), counter and CAN
  • MSI compatibility for charge, thermocouple and LVDT input

The most user friendly data acquisition software OXYGEN will lead you to very quick and reliable measurement results.

TRION-MULTI Interfaces: CAN, Voltage, Current, IEPE, Bridge, RTD, Counter, Resistance, MSI

INPUT TYPES RANGES SUPPORTED SENSORS
Voltage Voltage Icon
±2 mV to ±100 V freely programmable
IEPE® Vibration Icon
100 mV to ±10 V freely programmable IEPE® sensors
Bridge Bridge Icon
1 to 1000 mV/V 4-, 5-, 6-wire full bridge; 3-, 4-, 5-wire ½ bridge;
2-, 3-, 4-wire ¼ bridge; 120 / 350 / 1000 Ω
Resistance Potentiometer Icon
10 Ω to 30 kΩ Potentiometer, resistance temperature detection:
Pt100, Pt200, Pt300, Pt500, Pt2000 (2-, 3-, 4-wire)
Current ±30 mA 4 to 20 mA sensors;
loop powered sensors
CAN CAN Icon CAN 2.0
MSI Modular Smart Interfaces Icon
MSI-BR-CH-x: 500 to 50000 pC
MSI-BR-TH-x: various TC ranges
MSI-BR-LVDT
LVDT, RVDT, charge output and thermocouple sensors
Voltage input accuracy ≤10 V DC
0.1 Hz to 10 kHz
10 kHz to 50 kHz
50 kHz to 100 kHz
±0.02 % of reading, ±0.02 % of range ±20 μV
±0.02 % of reading, ± 0.02 % of range ±20 μV
±0.1 % of reading, ± 0.02 % of range ±20 μV
±0.5 % of reading, ± 0.02 % of range ±20 μV
Input impedance Differential (100 MΩ or 1 MΩ), Single ended (50 MΩ)
Input coupling DC/AC (highpass filter 0.16 Hz to 100 Hz freely programmable)
Spurious free SNR (10 V range) 1 kS/s to 200 kS/s: 140 dB

Isolated highspeed inputs

The TRION(3)-18xx-MULTI modules are faster than any other similar module on the market. Some of the keyfacts are:

  • Simultaneous sample rate of up to 5 MS/s
  • Analog bandwidth of 2 MHz
  • Continuous data streaming to application and disk
  • Channel to channel, channel to ground, both isolated (350 V)
  • For DEWE2 (2 MS/s) and DEWE3 (5 MS/s)

Onboard filtering and signal processing

To provide excellent signal to noise ratio and aliasing free data, we equipped the module with:

  • Analog anti-aliasing filter
  • Precise lowpass filter with Bessel and Butterworth characteristic up to 8th order with freely programmable cutoff frequency
  • AC-coupling programmable (0.16 Hz to 100 Hz)
  • Linearization of RTD and thermocouple sensors

ultra-low noise and distortion

Analog circuit design and AD-conversion at a glance. Better performance than any other 24-bit highspeed measurement system.

  • Outstanding dynamic range (140 dB)
  • Highest accuracy also for AC
  • Market leading number of effective bits
  • Best solution for analysis of dynamic signals in mechanical structure analysis
  • THD -108 dB at 1 kHz

Powerful excitation

Voltage and current controlled sensor excitation for almost every sensor type. There is enough power to supply sensors with high demand as well:

  • 0 to 24 V with up to 100 mA (max. 0.5 W)
  • 0.1 to 60 mA with up to 24 V (>20 mA: 10 V)
  • Highest accuracy of 0.02%
  • No power sharing between individual inputs

 

 

Back to top
Contact us Contact us

Do you have a question?

Kontakt-Formular